110V440ah lead-acid battery device is applied in the 8ton 110V battery locomotive, each battery is 2V, capacity is 440AH.
110V440ah anti-explosion lead-acid battery for 8 ton locomotive
110V lead-acid battery device is applied in the 8 ton 110V battery locomotive, each battery cell is 2V, capacity is 440AH.
Dimensions: 2400*1050*570(mm)
Specification: 2 Voltage/ unit, consist of 55 units, capacity is 440ah
Operation Method of lead-acid battery device
1. Please open the battery cover before charging. In order to avoid the temperature of the battery during charging and the volatile pressure of the electrolyte being too high, the battery case may be deformed and the battery may be damaged.
2. Pay attention to the amount of electrolyte in the battery. According to the cover plate 1-2 cm, if it is lower than the plate, please add distilled water immediately.
3. Pay attention to the electrolyte concentration. Measure with a hydrometer, add water or electrolyte in time.
4. Note that the temperature of the electrolyte must not exceed 45°C. If it exceeds the temperature, it needs to be powered off to cool down or cool down with cold water.